Tandberg Data DPS Expansion Module Disk Pack Specifiche Pagina 45

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 44
Troubleshooting | 39
Check for excessive recirculation of heated air from rear to the front.
If possible, shut down the enclosure and investigate the problem before continuing.
Contact Support to replace the cooling fan module.
Thermal warnings
If the OPS panel System Fault LED and Logical Fault LED are ON and all drive LEDs are
flashing or an audible alarm sounds continuously and cannot be muted, this may signal a
thermal warning.
This can happen when one of the following occurs:
The enclosure temperature is at a higher threshold than the thermal alarm. (This should
already have been activated).
All fans have failed.
Only one fan is operating and the internal temperature is 40°C (104°F) or above.
If this occurs, take the following actions:
Switch off immediately.
Check for airflow restrictions.
Check power supply module faults.
Check for excessive local temperatures.
Vedere la pagina 44
1 2 ... 40 41 42 43 44 45 46 47 48 49 50 ... 67 68

Commenti su questo manuale

Nessun commento