41
Upgrading DPS Expansion Module
If DPS Expansion Module is deployed in your environment to provide external storage and
you are upgrading DPS1000 Series, you may have to upgrade the DPS Expansion Module
firmware. Complete the following steps to upgrade to the latest firmware version.
1. Obtain a computer that can be used to connect to DPS Expansion Module.
2. Obtain the latest firmware by contacting Support. Save the .bin files on the computer you
will use to connect to and upgrade DPS Expansion Module.
3. Connect the serial cable included with DPS Expansion Module from the serial port on the
DPS Expansion Module controller to a COM port on the computer.
4. Obtain the IP address of DPS Expansion Module. The following steps demonstrate how to
access DPS Expansion Module from Microsoft Windows using HyperTerminal. You can
use other terminal programs as well.
a. From the Start menu, select Programs→Accessories→Communications→
HyperTerminal.
b. In the HyperTerminal connection wizard, enter a connection name, choose an icon to
associate with the connection, and click OK.
c. In the Connect To dialog box, select a communications port and click OK.
COM1 is the port used by most systems. If your system does not use this port, contact
your system administrator to determine the port.
Depending on your version of HyperTerminal, you may be required to click the
Configure button to display the Properties dialog box for the selected communications
port.
d. In the Properties dialog box, set the following information:
• Bits per second = 115200
• Data bits = 8
•Parity = None
• Stop bits = 1
• Flow control = None
e. Click OK.
f. Press Ctrl+e to open the console menu.
g. Enter 2 (Diagnostics).
h. Enter 6 (StorView Embedded Module Support).
i. Enter 2 (Enter StorView Embedded Module Menu Mode (Exit with CTRL-W)).