Environment
Ambient Temperature and Humidity
Temperature
Range
Relative Humidity Max. Wet Bulb
Operational 5°C to 40°C
(41°F to 104°F)
8% to 80%
non-condensing
23°C (74°F)
Non-Operational 1°C to 50°C
(34°F to 122°F)
8% to 80%
non-condensing
27°C (80°F)
Storage 1°C to 60°C
(34°F to 140°F)
8% to 80%
non-condensing
29°C (84°F)
Shipping -40°C to 60°C
(-40°F to 140°F)
5% to 100%
non-precipitating
29°C (84°F)
Airflow System must be operated with low pressure
rear exhaust installation.
(Back pressure created by rack doors and
obstacles not to exceed 5 pascals [0.5 mm
water gauge].)
Altitude, Operational 0 to 3045 m (0 to 10,000 ft)
Altitude, Non-Operational -305 to 12,192 m (-1000 to 40,000 ft)
Shock, Operational Vertical axis 5 g peak 1/2 sine, 10 ms
Shock, Non-Operational 30g 10 ms 1/2 sine
Vibration, Operational 0.21grms 5-500 Hz Random
Vibration, Non-Operational 1.04grms 2-200 Hz Random
Vibration, Relocation 0.3g 2-200 Hz sine
Acoustics Sound Power Operating:
Less than 58 dB LwA measured at 23°C
(74°F).
Sound Pressure Operating:
Less than 6.8 Bels LwA measured at 23°C
(73°F).
Orientation & Mounting 19” Rack mount (2 EIA Units).
Rack Rails To fit 800 mm (31.50 inches) depth racks
compliant with IEC 297.
Rack Characteristics Back pressure not exceeding 5 pascals (0.5
mm water gauge).